Laboratory Equipments › Mechanical / Industrial Engineering<Back |
COMPUTERIZED AIR CONDITIONING CYCLE TEST RIG MODEL AC002 |
click on image to zoom
|
IEICOS COMPUTERIZED AIR CONDITIONING CYCLE TEST RIG is:
1. used study the basics of air conditioning systems and components used in airconditioning system .
2. understand the principles of air conditioning cycle..
3. designed for experimental determination of
a. Refrigeration Effect,
b. Work Input,
c. Actual C.O.P.,
d. Carnot C.O.P.,
e. Theoretical C.O.P.,
f. Relative C.O.P.,
g. Ton of Refrigeration,
h. Plant Efficiency.
IEICOS AIR CONDITIONING CYCLE TEST RIG is designed with standard industry state-of-the-art components to help the students knowledge about currently available products and components. The system is self contained with a full fledged easy access control panel with various meters, displays, switches and indicators. The system consists of:
Anemometer |
: |
Vane type provided to measure air flow |
Air Duct |
: |
0.25m x 0.25 m |
Boiler |
: |
Electrically fired small boiler for maintaining humidity of air with electrical heater |
Blower |
: |
1 HP capacity centrifugal blower with air control arrangement.. |
Compressor |
: |
Hermetically sealed compressor |
Condenser |
: |
Air Cooled Condenser made out of copper pipe |
Condensor Cooling |
: |
Aluminum fins of matching capacity with fan cooling |
Evaporator |
|
Evaporator coils carrying refrigerant fixed in the air duct and the air passing through comes in contact with the coils & gets cooled. |
Expansion device |
: |
Thermostatic expansion valve |
Energy Meter |
: |
For power measurement of compressor |
Pressure Gauge |
: |
High Pressure and Low Pressure measurement – 2 Nos |
Rotameter |
: |
for refrigerant flow measurement |
Thermocouples |
: |
Set of six thermocouples with Digital Temperature Indicator |
Switches |
: |
For compressor, condenser fan, dehumidifier heater, boiler and blower |
Voltmeter |
: |
0 - 250 V |
Ammeter |
: |
0 - 15 A |
Power Transmitter |
: |
Power measurement of compressor – 1 No |
Pressure Transmitter |
: |
High Pressure measurement, Low Pressure measurement - 2 Nos |
Flow Transmitter |
: |
Refrigerant flow measurement |
COMPUTER AND SOFTWARE:
COMPUTER:
Latest available configuration supplied
Typical Configuration – Intel Core 2 Duo, 320 GB HDD, 2 GB RAM, CD/DVD-RW, 101 Keyboard, Optical Mouse, 17” Flat Panel Monitor, 2/4 USB ports and 1 serial port or better will be supplied
SCADA SOFTWARE:
• Mimic diagram of the experimental setup
• Operational Modes – Auto, manual and other control modes of on/off, PID control
• Data Acquisition, monitoring and control
• Menu driven software with easy user interface screens
• Graphical real-time plotting
• Data storage, archival, retrieval and graphing facilities
• Setpoint controls with alarms
DIMENSIONS (Nominal): 3.0 m. (L) x 1.0 m. (W). x 0.8 m (D) plus space for computer
WEIGHT : 180 Kg
POWER SUPPLY: 230V/440 V. A.C., 50 Hz.
|
|
|
|
|
|
|
|
|
|
|
|
|
203, 12th Main Road, 3rd Phase
Peenya Industrial Area
Bangalore - 560 058
Email : marketing@ieicos.com
Tel No : +91 80 2839 4520 |
|
|
|
|
|