Laboratory Equipments › Mechanical / Industrial Engineering<Back |
COMPUTERIZED REFRIGERATION CYCLE TEST RIG MODEL REF002 |
click on image to zoom
|
IEICOS COMPUTERIZED REFRIGERATION CYCLE TEST RIG is:
1. used study the basics of refrigeration systems and components used in refrigeration system.
2. understand the principles of Vapor compression Refrigeration cycle.
3. designed for experimental determination of
a. Refrigeration Effect,
b. Work Input,
c. Actual C.O.P.,
d. Carnot C.O.P.,
e. Theoretical C.O.P.,
f. Relative C.O.P.,
g. Ton of Refrigeration,
h. Plant Efficiency.
IEICOS COMPUTERIZED REFRIGERATION CYCLE TEST RIG is designed with standard industry state-of-the-art components to help the students knowledge about currently available products and components. The system is self contained with a full fledged easy access control panel with various meters, displays, switches and indicators. The system consists of:
Compressor |
: |
Hermetically sealed compressor. |
Condenser |
: |
Air Cooled Condenser made out of copper pipe |
Condensor Cooling |
: |
Aluminum fins of matching capacity with fan cooling |
Dimmerstat |
: |
to control power supply to heater. |
Evaporator |
: |
Copper Coil immersed in water. The evaporator is insulated from outside to prevent heat loss. |
Expansion device |
: |
Capillary Tube & Thermostatic expansion valve. |
Energy Meter |
: |
One each for power measurement of compressor & evaporator heater. |
Filter/drier |
: |
Provided |
Heater |
: |
Immersion type electric heater |
Pressure Gauge |
: |
High Pressure and Low Pressure measurement – 2 Nos |
Rotameter |
: |
for refrigerant flow measurement |
Service Valve |
: |
Hand Shut Off type |
Solenoid valve |
: |
Provided |
RTD Sensors |
: |
Set of six sensors with Digital Temperature Indicator/Transmitter |
HP-LP Cutout |
: |
Make Danfoss or Equivalent |
Switches |
: |
For compressor, condenser fan, solenoid valve & evaporator heater. |
Voltmeter |
: |
0 - 250 V |
Ammeter |
: |
0 - 15 A |
Thermostat |
: |
Provided of reputed make |
Power Transmitter |
: |
Power measurement of compressor & evaporator heater. – 2 Nos |
Pressure Transmitter |
: |
High Pressure measurement, Low Pressure measurement - 2 Nos |
Flow Transmitter |
: |
Refrigerant flow measurement |
COMPUTER AND SOFTWARE:
COMPUTER:
Latest available configuration supplied
Typical Configuration – Intel Core 2 Duo, 320 GB HDD, 2 GB RAM, CD/DVD-RW, 101 Keyboard, Optical Mouse, 17” Flat Panel Monitor, 2/4 USB ports and 1 serial port or better will be supplied
SCADA SOFTWARE:
• Mimic diagram of the experimental setup
• Operational Modes – Auto, manual and other control modes of on/off, PID control
• Data Acquisition, monitoring and control
• Menu driven software with easy user interface screens
• Graphical real-time plotting
• Data storage, archival, retrieval and graphing facilities
• Setpoint controls with alarms
DIMENSIONS (Nominal): 1.5 m. (L) x 1.0 m. (W). x 0.8 m (D) plus space for computer
WEIGHT : 180 Kg
POWER SUPPLY: 230V/440 V. A.C., 50 Hz.
|
|
|
|
|
|
|
|
|
|
|
|
|
203, 12th Main Road, 3rd Phase
Peenya Industrial Area
Bangalore - 560 058
Email : marketing@ieicos.com